A serene indoor swimming pool reflects warm ceiling lights and large floor-to-ceiling windows. Wooden lounge chairs line the far side of the pool, facing the expansive outdoor view. Soft, golden lighting and natural materials create a calm, upscale spa atmosphere. Trees and landscape outside add a peaceful, nature-inspired backdrop to the relaxing interior setting.

Gullmar fjord powers a more efficient Vann Hotel and Spa

The Vann Hotel and Spa uses energy from the Gullmar fjord and NIBE heat pumps to reduce purchased energy by around 850,000 kWh per year.

NIBE heat pumps use energy from the fjord for heating and cooling

Background
background

At Vann Hotel and Spa on Sweden’s west coast, energy from the Gullmar fjord has been part of the property’s heating system since 1984. A major modernisation with NIBE heat pumps helped reduce purchased energy by around 850,000 kWh per year.

Vann Hotel and Spa is located by the Gullmar fjord in Bohuslän, Sweden. The 17,500 m² property includes 160 hotel rooms, conference facilities and a spa with eight heated indoor and outdoor pools.

Energy efficiency has been part of the property since it opened in 1984. The facility was then owned by the Metall trade union, which invested in a technically advanced energy solution for the time.

Heat pumps were used to extract energy from the water of the Gullmar fjord, while exhaust air recovery helped make use of energy from the building. The system supplied heating, hot water and energy for the heated pool.

Aspelin Ramm became the owner in 2008 and continued to develop both the hotel and its energy system.

According to property manager Roger Larsson, reducing the amount of purchased energy was an important part of the owner’s long-term environmental work. The original energy concept therefore remained central to the property more than three decades after the hotel first opened: make use of the energy available in the fjord and continuously improve how efficiently the facility operates.

Aided by the water of the Gullmar fjord and NIBE’s excellent ground-source heat pumps, we have managed to tweak our facilities to a fantastic degree.
Project: Vann Hotel and Spa.
Property: 160 rooms, spa and conference facilities over approximately 17,500 m². Eight heated indoor and outdoor pools.
Location: Gullmar fjord, Bohuslän, Sweden.
Heating solution: NIBE ground source heat pumps, ventilation, exhaust air recovery, control and monitoring.
Heat source: Water from the Gullmar fjord.
Additional energy source: Approximately 1,200 m² of solar panels.
Result: Around 850,000 kWh reduction in purchased energy per year.

F1345 ground source heat pump

Ground source heat pump

F1345

A contemporary building complex surrounds a landscaped courtyard filled with lush greenery and gravel paths. Raised rust-colored planters curve through the garden, leading toward dark-clad structures with metal roofs and awnings. Large sculptural letters spelling "VANN" stand prominently among the plants, serving as a focal point. The soft evening light and muted color palette create a calm, welcoming atmosphere.

Energy efficiency built in from the start

Although the original system was advanced when it was installed, the facility had been developed over many years and had become complicated to manage.

In 2016, Vann Hotel and Spa carried out an energy analysis and reviewed how the energy system was built up.

The review led to a broader modernisation of the property’s technical systems. Rather than focusing on one individual component, the project included new ventilation units, new heat pumps and updated control and monitoring systems.

The hotel also decided to invest in a large solar PV installation.

The ambition was to further reduce energy use while continuing to make use of the Gullmar fjord as the source for the heat pump system.

For installer Jonas Gustafsson of Jonas Rör AB, the existing equipment room showed the scale of the challenge. The task was therefore not simply to replace old heat pumps. The different parts of the energy system needed to be modernised and brought together in a solution that was easier to operate.

Modernising a pioneering but complex energy system

Unlike a conventional ground source heat pump installation, the system at Vann Hotel and Spa does not collect energy from boreholes.

Instead, two approximately 100-metre-long pipes bring water from the fjord to an equipment building by the pier. A heat exchanger transfers energy from the fjord water to a brine circuit.

From there, the energy is transported to the technical installation beneath the hotel, where NIBE ground source heat pumps use it to provide heating and cooling for the property.

According to the original project, using the fjord meant that the hotel avoided the need to drill more than 50 boreholes that would otherwise have been required.

As part of the modernisation, six NIBE ground source heat pumps were installed. The project later included plans for two additional units as the system was further developed.

New ventilation units and updated control and monitoring systems were also introduced.

For Jonas Gustafsson, one of the main advantages was the move towards a more complete system solution.

“By investing in an entire system solution and taking a holistic approach, we modernised the facility and considerably simplified operations.”

The property’s energy system was also complemented with approximately 1,200 m² of solar panels. According to the project information, the solar installation was expected to generate around 170,000 kWh per year.

Together, the investments combined the existing energy source in the Gullmar fjord with newer heat pump technology, ventilation, control and solar power.

By investing in an entire system solution and taking a holistic approach, we modernised the facility and considerably simplified operations.

Three technicians stand side by side in an industrial interior, facing the camera. They appear to be technicians or engineers, wearing work clothes and casual attire with tools visible on a belt. Behind them are large white technical units and exposed pipes on the ceiling, suggesting a mechanical or utility room. The lighting is bright and even, highlighting the subjects and equipment.

850,000 kWh less purchased energy per year

The modernisation produced substantial reductions in purchased energy.According to the project figures, Vann Hotel and Spa reduced its energy use by approximately 850,000 kWh per year.

Energy use per overnight guest and day was reported to have fallen from approximately 85 kWh to 43 kWh, a reduction of almost 50 percent.The property also reduced its electrical power requirement by around 30 percent, from approximately 700 kW to 500 kW.

At the time of the case, total energy use had been reduced to around 140 kWh per square metre.

For owner Aspelin Ramm, however, the improvements were not seen as the end of the work. The project built on an energy principle first introduced at the hotel in 1984. Instead of abandoning the original concept, the property continued to develop it with newer technology.

The Gullmar fjord remained the source of energy for the heat pump system, while NIBE heat pumps, updated ventilation and control systems helped make the overall installation more efficient and easier to operate.

For Vann Hotel and Spa, the result was a significant reduction in purchased energy while retaining the distinctive local energy source that had been part of the property from the beginning.